Application |
Joint Sizes |
Description |
Product |
Product Image |

FIRE-RATED
Top and Intermediate
Decks; Treads and Risers; Parking Decks;
Perimeter Joints--Stair Towers, Elevator Towers, New-To-Existing Slabs;
Joint-Face-Adhered
Watertight, Traffic Durable, high movement AND 2-HOUR FIRE-RATED.
One install does it all.
|
1" to 4" max.
(25 - 100mm)
Movement:
+25% & -25%
(Total 50%)
|
Structural expansion joint.
Joint-face adhered (no blockouts required). System provides
watertightness, 2-hour fire-rating, trafficability in a single
installation without need for fire-blankets, mineral wool, fire-caulks
etc. |
EMSHIELD DFR2
water--fire--traffic--movement
One
product, one install, does it all. |

|

Fire-Rated Expansion Joints
Walls and Vertical Rises |
1" to 6"
(25 - 150mm)
Movement:
+25% & -25%
(Total 50%) |
UL Tested and
Certified 2-hour Fire Rated single unit expansion joint. Watertight and
energy-efficient. Coated both sides in choice of 12 colors. |
EMSHIELD WFR2
|
 |
| Top and Intermediate
Decks;
Tee-to-Tee
and other Control Joints; Perimeter joints:
Watertight-Joint-Face Adhered:
|
1" to 4"
(25 - 100mm) |
Structural
Joints--Joint-Face Adhered system for new and retrofit in concrete and
embedded metal angle substrates. |
DSM SYSTEM |
 |
Treads &
Risers;
Large,
and Seismic Top and Intermediate Decks:
|
4"
to 24"
(100 - 600mm)
Movement:
+50% & -50%
(Total
100%) |
Compression anchored coverplate system, sound dampened and free of any
mechanical fasteners, embeds, centering bars, etc. |
SJS SYSTEM |
 |
Treads &
Risers; Top and Intermediate
Decks-Blockout Mounted:
|
1" to 5-1/2" max.
(25 - 140mm)
Movement Range: From 1/2" up to 6"
(consult product data)
|
Structural expansion joints. Winged
Seals with high-impact,
low-aggregate,
impact, shock and sound absorbing flexible nosing material. |
THERMAFLEX |

TM System

TCR System |
Stair and
elevator vestibules:
|
4"
to 24"
(100 - 600mm) |
DSM SYSTEM at perimeters with watertight transition
to SJS Coverplate System across pedestrian areas. |
DSM SYSTEM
and
SJS SYSTEM |

 |
|
Concourses; Split Slabs, Plazas,
Overlays:
|
Up to 6-inch (150mm) max.
mean joint.
|
Structural openings in split slabs with watertight integration into
buried waterproofing membrane. Asphalt, concrete, paver overlay |
MIGUTAN FP/...Series |
 |
Large and
Seismic Joints in Split Slabs; Concourses, Plazas:
|
4"
to 24"
(100 - 600mm) |
mean joint openings in split slabs with watertight integration into
buried waterproofing membrane. Asphalt, concrete, paver overlay. |
SJS FP SYSTEM |
 |
|
Vertical-Plane Joints:
|
3/8"
to 12"
(6 - 300mm) |
Exterior
Walls, Parapets, Light Walls, Elevator and Stair Tower Abutment Joints; Interior
walls of boxes, suites, booths, vending, bathrooms, etc.. |
SEISMIC COLORSEAL |
 |
Limited Depth Vertical
Plane Joints:
|
1"
to 12"
(25 - 300mm) |
Narrow-Width
Walls and Parapets, Mullions, Curtainwall--both
sides sealed with custom depth, double or triple-sided silicone bellows
in single installation. |
SEISMIC COLORSEAL
DS (Double Sided) |
 |
|
Interior
Floors:
|
3/8"
to 24"
(8 - 600mm) |
Suites, Offices,
Locker Rooms, Elevator lobbies, Conference Spaces, etc.
Note: Not watertight--for interior use only.
Joints from 1 - 4 inches can be waterproofed and fire-rated with
installation of EMSHIELD DFR2
beneath the MIGUTRANS. |
MIGUTRANS
&
MIGUTRANS TWINSERT |
 |
|
Below-Grade
Walls-Positive Side Accessible:
|
3/8"
to 12"
(8 - 300mm) |
Freestanding with installation access from positive side. |
20H
SYSTEM |
 |
Below-Grade
Walls-Blind Side:
|
2"
(50mm) |
Blind-side formed in lagging. |
BG